In actual use high-pressure Raymond mill, this kind of equipment due to the operation of some error or other reasons, resulting in abnormal, the operation of such equipment is inevitable. So how do we solve this?
In the case of different faults, we need to adopt different methods in the maintenance of the actual high-pressure Raymond mill.
If there is an abnormal vibration in the body of the high-pressure Raymond mill, it is likely that the mechanical extrusion pressure imbalance caused by the uneven particle size of the material. Therefore, we need to adjust the average particle size of the incoming material according to the size of the particle, so as to normalize the extrusion of the high-pressure Raymond mill.
If the high-pressure Raymond mill run when the pressure is too low and associated with the cylinder oil leak case, you probably due to mechanical problems of hydraulic system, then we need to replace the damaged parts timely, and clean the hydraulic oil, and then to carry out the corresponding debugging, this can make the machine back to normal use.
When the high-pressure Raymond mill at work when the bearing temperature anomaly, could be due to failure of the lubrication system, so we will handle all lubricating points in time carelessly, and the related parts to clean, to ensure the normal operation of circulating cooling water.