If you are interested in our products, Please get in contact with us .
E-mail: shuguang_mill@163.com Chat Line Send InquiryCommon faults: fan vibration.
Cause: 1. Uneven powder or wear on the fan. 2. Anchor bolts are loose.
Removal method: 1. Remove the blade product or replace the blade 2. Tighten the anchor bolts.
Common faults: transmission device and analyzer fuel tank heating.
Causes: the oil viscosity is large, oil thick, the thread pump oil can not hit, make the upper bearing short of oil.
Troubleshooting: 1. Check whether the brand and viscosity of oil are in accordance with requirements. 2. Check the operation direction of the analyzer.
Common faults: wear parts of grinding rod into powder bearing.
Cause: 1. Lack of oil or sealing ring. 2. Lack of maintenance and cleaning for a long time.
2. Regular cleaning and replacement of oil seal.